Hefei NMP Recovery System
Basic parameters and configuration:
![]() |
![]() |
workmanship |
Positive electrode: waste heat recovery+water washing return air / Negative electrode: waste heat recovery+condensation+water washing |
|
recovery unit Design parameters |
Waste gas treatment capacity |
Positive pole: 180000Nm ³/ h. Negative electrode sleeve: 120000Nm ³/ h. Set |
Tail gas emission concentration |
≤ 25mg/m ³ |
|
NMP recovery rate |
≥ 99% |
|
NMP recovery solution concentration |
≥ 85% |
|
Design service life |
15 years |
|
Heat recovery efficiency |
≥ 75% |